Product Name: |
fingertip oximeter(CMS50E)
|
Supply Ability: |
1000 |
Related proudcts |
pulse oximeter, oximeter, fingertip oximeter, |
Specifications |
57*32*30 |
Price Term: |
CIF |
Port of loading: |
Beijing |
Minimum Order |
1 |
Unit Price: |
139 |
|
Major Features
■Integrated with SpO2 probe and processing display module ■Small in volume、light in weight and convenient in carrying ■Operation of the product is simple ,low power consumption ■Operation menu for the function setting ■SpO2 value display ■Pulse rate value display, bar graph display ■Pulse waveform display ■The display mode can be changed ■Screen brightness can be changed ■A pulse rate sound indication ■With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable ■Battery capacity indication ■Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function ■With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers ■Real-time data can be transmitted to computers ■Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe ■Wireless communication(CMS50EW) ■RF Wireless communication function(Option)(Only applied for Ver6.6R or above) ■Connected with an external oximeter probe(Option)(CMS50EW, only applied for Ver6.6R or above of CMS50E)
Main performance
Display Mode: 1.3" 65K Color OLED display Screen Resolution: 128*96 SpO2 Measuring Range: 0%?00%, (the resolution is 1%). Accuracy: 70%?00%: ±2% ,Below 70% unspecified. PR Measuring Range: 30bpm?50bpm, (the resolution is 1bpm) Accuracy: ±2bpm or ±2% (select larger) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger). Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Power Consumption: less than 100mA Voltage: DC 3.6V?.2V Power Supply |
Company: |
Contec Medical Systems Co., Ltd.
|
Contact: |
Ms. Chelsea Yang |
Address: |
No.112 Qinhuang West Avenue,Economic and Technical Development Zone,Qinhuangdao,Hebei,China, |
Postcode: |
066004 |
Tel: |
86-335-8015468 |
Fax: |
86-335-8015590 |
E-mail: |
|
|
|
|